留下您的信息
ALL ALUMINUM ALLOY CONDUCTORS (AAAC)
Cable Materials

Products

ALL ALUMINUM ALLOY CONDUCTORS (AAAC)

Introduction

It is widely used in overhead transmission and distribution lines.

    llytm0
    Advantage

    ●The conductor is composed by bare concentric-lay-stranded aluminum alloy wires.

    ●Standard : IEC 61089, ASTM B399, BS 3242, DIN 48201/6, AS 1531.

    ●Packing : Wooden drum, Plywood drum, Steel drum.

    Specification

    A2 CONDUCTOR IEC 61089-1991

    Specific

    Nominal Sectional Area

    mm²

    Number of Wires

    Diameter

    mm

    Linear Density

    Kg/km

    Breaking Load

    KN

    D.C. Resistance

    Ω/km

    Single wire

    Strand wire

    16

    18.4

    7

    1.83

    5.49

    50.4

    5.43

    1.7896

    25

    28.8

    7

    2.29

    6.86

    78.7

    8.49

    1.1453

    40

    46.0

    7

    2.89

    8.68

    125.9

    13.58

    0.7158

    63

    72.5

    7

    3.63

    10.9

    198.3

    21.39

    0.4545

    100

    115

    19

    2.78

    13.9

    316.3

    33.95

    0.2877

    125

    144

    19

    3.10

    15.5

    395.4

    42.44

    0.2302

    160

    184

    19

    3.51

    17.6

    506.1

    54.32

    0.1798

    200

    230

    19

    3.93

    19.6

    632.7

    67.91

    0.1439

    250

    288

    19

    4.93

    22.0

    790.8

    84.88

    0.1151

    315

    363

    37

    3.53

    24.7

    998.9

    106.95

    0.0916

    400

    460

    37

    3.98

    27.9

    1268.4

    135.81

    0.0721

    450

    518

    37

    4.22

    29.6

    1426.9

    152.79

    0.0641

    500

    575

    37

    4.45

    31.2

    1585.5

    169.76

    0.0577

    560

    645

    61

    3.67

    33.0

    1178.4

    190.14

    0.0516

    630

    725

    61

    3.89

    35.0

    2000.7

    213.90

    0.0458

    710

    817

    61

    4.13

    37.2

    2254.8

    241.07

    0.0407

    800

    921

    61

    4.38

    39.5

    2540.6

    271.62

    0.0361

    900

    1036

    91

    3.81

    41.8

    2861.1

    305.58

    0.0321

    1000

    1151

    91

    4.01

    44.1

    3179.0

    339.53

    0.0289

    1120

    1289

    91

    4.25

    46.7

    3560.5

    380.27

    0.0258

    1250

    1439

    91

    4.49

    49.4

    3973.7

    424.41

    0.0231

    A3 CONDUCTOR IEC 61089-1

    Specific

    Nominal Sectional Area

    mm²

    Number of Wires

    Diameter

    mm

    Linear Density

    Kg/km

    Breaking Load

    KN

    D.C. Resistance

    Ω/km

    Single wire

    Strand wire

    16

    18.6

    7

    1.84

    5.52

    50.8

    6.04

    1.7896

    25

    29.0

    7

    2.30

    6.90

    79.5

    9.44

    1.1453

    40

    46.5

    7

    2.91

    8.72

    127.1

    15.10

    0.7158

    63

    73.2

    7

    3.65

    10.9

    200.2

    23.06

    0.4545

    100

    116

    19

    2.79

    14.0

    319.3

    37.76

    0.2877

    125

    145

    19

    3.12

    15.6

    399.2

    47.20

    0.2302

    160

    186

    19

    3.53

    17.6

    511.0

    58.56

    0.1798

    200

    232

    19

    3.95

    19.7

    638.7

    73.20

    0.1439

    Leave Your Message