Leave Your Message
0835 Cross-linkable Semi-conductive Outer Shielding Compound

Cable Materials

Products

0835 Cross-linkable Semi-conductive Outer Shielding Compound

Introduction

0835 cross-linkable semi-conductive shielding compound is used as strippable insulation shield for cross-linked polyethylene insulation power cable rated voltage up to 35KV. It’s suitable for high temperature vulcanization processing method. 0835provides excellence processability, fine surface smoothness, stable volume resistivity, low pre-cure or scorch characteristic,lower stripping force with anti-tearing property, leaving clean surface for insulation after stripped.

    me26i9
    Advantage

    ●Packing: In Cardboard Box with inner PE bag, 600kg/box.

    ●Storage: Should be stored at room temperatures between 10~30°C. Recommended maximum storage period in dry and clean are 12 months unopened and in original packaging after the manufacture.

    Specification & Parameter

    Technical Parameter

    Property

    Test Method

    Unit

    Value

    Density at 23°C

    ASTM D 1505

    g/ cm3

    ≤ 1.13

    Tensile Strength (200 mm/min)

    Tensile Strength Retention

    (Heat Aging at 135°C after 168h)

    ASTM D 638

    MPA

    %

    ≥ 13

    85

    Elongation at Break before ageing

    Elongation Retention

    (Heat Aging at 135°C after 168h)

    ASTM D 638

    %

    %

    280

    85

    Volume Resistivity at 20°C

    Volume Resistivity at 90°C

    ASTM-D991

    W.cm

    W.cm

    60

    ≤ 600

    Hot Set Test Conditions

    At 200 ±2 °C x 0.2 MPa for 15 min

    IEC 540-14

     

     

    Elongation after loading

    Permanent Deformation

     

    %

    %

    ≤ 60

    ≤ 2

    Moisture Content

    KARL FISCHER

    ppm

    ≤ 500

    Brittleness Temperature

    ASTM-D746

     

    -40°C

    Stripping Force

    Q/TNYM 1-2012

    N/cm

    15

    Processing Conditions

    The recommended standard extrusion temperature profiles are as followings: Unit: °C

    Zone

    Zone 1

    Zone 2

    Zone 3

    Zone 4

    Flange

    Tube

    Screw

    Temperature Range°C

    80-85

    90-95

    100-105

    105-110

    105

    105

    50-55

    We suggest using double layer filter mesh with size 40 mesh (350μm).

    We recommend hopper drying at 40~60'C for 4 hours to remove moisture before extrusion.